Subsections

ActiveChannel

The Model

Generic active channel with arbitray number of ion gates . g(t,Vm) is computed as


where is the maximal conductance, and is fraction of i-type gates currently open.

Note that no specific gates are modeled. Instead arbitrary ion gate objects can be connected to the channel.

Read/writable Fields

Gbar (S) :
The maximum conductance of the channel;
Erev (V) :
The reversal potential Erev of the channel

Readonly Fields

g (S) :